Search results for "Low permeability"
showing 5 items of 5 documents
Usefulness of Caco-2/HT29-MTX and Caco-2/HT29-MTX/Raji B Coculture Models To Predict Intestinal and Colonic Permeability Compared to Caco-2 Monocultu…
2017
The Caco-2 cellular monolayer is a widely accepted in vitro model to predict human permeability but suffering from several and critical limitations. Therefore, some alternative cell cultures to mimic the human intestinal epithelium, as closely as possible, have been developed to achieve more physiological conditions, as the Caco-2/HT29-MTX coculture and the triple Caco-2/HT29-MTX/Raji B models. In this work the permeability of 12 model drugs of different Biopharmaceutical Classification System (BCS) characteristics, in the coculture and triple coculture models was assessed. Additionally, the utility of both models to classify compounds according to the BCS criteria was scrutinized. The obta…
Development of an ion-pair to improve the colon permeability of a low permeability drug: Atenolol.
2016
Abstract To ensure the optimal performance of oral controlled release formulations, drug colon permeability is one of the critical parameters. Consequently developing this kind of formulations for low permeability molecules requires strategies to increase their ability to cross the colonic membrane. The objective of this work is to show if an ion-pair formation can improve the colon permeability of atenolol as a low permeability drug model. Two counter ions have been tested: brilliant blue and bromophenol blue. The Distribution coefficients at pH 7.00 (DpH7) of atenolol, atenolol + brilliant blue and atenolol + bromophenol blue were experimentally determined in n-octanol. Moreover, the colo…
Improvement of trospium-specific absorption models for fasted and fed states in humans
2014
The purpose of this study was to mechanistically interpret the oral absorption pattern of trospium in fasted and fed states by means of gastrointestinal simulation technology. A drug absorption model was built on the basis of experimental data. According to the generated model, low permeability across the intestinal epithelium, delayed gastric emptying time and a prolonged residence time in the small intestine are the key factors governing trospium absorption in the fasted state. Furthermore, in silico modelling provided a plausible explanation of the pronounced reduction in the oral bioavailability of trospium when administered with food. The simulation results support the decreased dissol…
IMI – Oral biopharmaceutics tools project – Evaluation of bottom-up PBPK prediction success part 3: Identifying gaps in system parameters by analysin…
2016
Three Physiologically Based Pharmacokinetic software packages (GI-Sim, Simcyp® Simulator, and GastroPlus™) were evaluated as part of the Innovative Medicine Initiative Oral Biopharmaceutics Tools project (OrBiTo) during a blinded “bottom-up” anticipation of human pharmacokinetics. After data analysis of the predicted vs. measured pharmacokinetics parameters, it was found that oral bioavailability (Foral) was underpredicted for compounds with low permeability, suggesting improper estimates of intestinal surface area, colonic absorption and/or lack of intestinal transporter information. Foral was also underpredicted for acidic compounds, suggesting overestimation of impact of ionisation on pe…
Benchmark study of undrained triaxial testing of Opalinus Clay shale: Results and implications for robust testing
2021
Triaxial testing of argillaceous rocks and shales is significantly more challenging than conventional rock mechanical testing. The challenges are mainly related to the very low permeability of these geomaterials, and their sensitivity to exposure of atmosphere and brines, which induces variations of water content, suction and effective stress. There are currently no international standards to guide service laboratories for robust testing procedures for shales. A benchmark study of undrained triaxial testing was therefore initiated with three leading service laboratories in shale testing, performing 13 tests and using two different methods of establishing sample saturation prior to deformati…